Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Сonnection of an electromagnetic lock and an exit button connected from the entrance panel, using the controlled output Lock on the panel 

...

Сonnection of an electromechanical lock and an exit button connected from the entrance panel, using the controlled output Lock on the panel 

...

Сonnection using two electromagnetic locks and two exit buttons, when connected to the panel via RS485 as a control interface 

...

Сonnection using two electromechanical locks and two exit buttons, when connected to the panel via RS485 as a control interface 

...

Opening delay time (for 8-pin module)

The delay module is equipped with a trimmer, which is responsible for the response time of the relay. This is the time at which the relays will switch from one position to another when the opening signal to them is received via the RS-485 interface, the Lock input, and the exit buttons are pressed.Image Removed

...

The use of electromagnetic locks

...

When connecting electromechanical locks, the trimmer must be turned to the left, and the delay time is adjusted in the range of 0.5 to 1 second. If necessary, the time can be slightly increased, but it is absolutely not recommended to set this time for more than 2 seconds!

Before mounting the reader, it is necessary to provide a hole or recess in the wall with dimensions 96×152×46 mm (for flush mounting). Dimensions of the bracket (flush box) = 94×151×45 mm. It is also necessary to provide for the supply of power cable, add. modules and local network.

body
Aura panel
tab1
styles{"body":{"text":{"color":"#02070e","textAlign":"left","fontWeight":"lighter","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#ffab0096","width":10,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
Info

When setting the delay time for more than 2 seconds and using electromechanical locks as part of a system, it is likely that these locks will fail, due to the technological features of the design of the magnetic coils in these types of locks!

...