height450px

To make a device chain with each other for communication and interaction via internal protocol we use logical addresses. They are required for all BAS-IP devices. This address corresponds to the location of the device within the territory and consists of Building No. (from 0001 to 9999), Unit No. (from 00 to 99), Floor No. (from 00 to 98), and Apartment No. (from 01 to 99). For example, a device in the 7th apartment, on the 2nd floor of the 1st unit in building No. 1 has a 0001-01-02-07 logical address. 

...

Logical addresses connections between devices

Widget Connector
overlayyoutube
_templatecom/atlassian/confluence/extra/widgetconnector/templates/youtube.vm
width750px
urlhttps://www.youtube.com/watch?v=oPDAMsoW1_s
height450px

To connect devices, they must have the same values for logical addresses. For example, the entrance panel is installed at the 1st unit of building No. 1, works in wall mode, and has logical address 0001. To call the monitor in apartment No 1, located on the 1st floor of the 1st unit, the monitor logical address (number) 0001-01-00-01 will be called. In this logical address, 0001 is a Building No., 01 stands for Unit No., 00 is a Floor No., and 01 is a number of apartment. Thus, the same logical address must be set in the monitor settings: building - 1, unit - 1, floor - 0, apartment - 1.