You can use this menu to set the parameters for the lock opening, door sensor input, elevator module, etc.

...

At this part, you can configure the functioning of 1 or 2 (when using SH-42) locks. The following parameters can be configured: 

  • Lock lock open time is a period (1-300 sec) during which relay contacts will be closed or open (depending on the lock type), and a lock will stay open;
  • Lock lock open delay is a period (1-300 sec) after which relay contacts will close or open after sending a signal to open a lock;
  • Impulse impulse opening mode: one or multiple pulses. It is available to set pulse duration and time between pulses for multiple pulses mode.;
Aura panel
tab1
styles{"body":{"text":{"color":"#02070e","textAlign":"left","fontWeight":"lighter","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#ffab0096","width":10,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]},"size":{}}}
body

If an electromechanical lock is used, it is recommended to select one impulse. If an electromagnetic lock is installed, we recommend setting multiple pulses for the lock correct and long functioning. These settings will help the locks work correctly and for a long time, especially mechanical as it might break if the voltage is applied to it for too long.

  • Keep the lock open or not if SIP registration is lost. It is necessary to set no sip SIP registration time for this parameter.     

...

Additional settings 

...

Here you can: 

  • Set set the Floor number for further features that work only with the lift elevator control module EVRC-IP;
  • Enableenable/disable features of sending the elevator to the indicated floor number when the lock is open from the monitor;.

Door sensor input 

...

It is possible to connect a door sensor or additional button to the door sensor input. In this section, you can enable/disable and configure their work.

...

4.  Choose the appropriate input mode:

    • Door door sensor mode is used to monitor the door state. If the door is not closed, after the expiration of the response time in Logs/Link logs will be shown that the door is open;
    • Door door entry button mode is recommended when the connected button is used as an additional, remote from the panel, entry button;. 

5. If you use Door sensor mode, set the Response time after which the mode will be activated.

...