You can use this menu to set the parameters for the lock opening, door sensor input, elevator module, etc.
Table of Contents |
---|
Locks management
At this part, you can configure the functioning of 1 or 2 (when using SH-42) locks. The following parameters can be configured:
- lock open time is a period (1-300 sec) during which relay contacts will be closed or open (depending on the lock type), and a lock will stay open;
- lock open delay is a period (1-300 sec) after which relay contacts will close or open after sending a signal to open a lock;
- impulse opening mode: one or multiple pulses. It is available to set pulse duration and time between pulses for multiple pulses mode;
Aura panel | ||||||
---|---|---|---|---|---|---|
| ||||||
If an electromechanical lock is used, it is recommended to select one impulse. If an electromagnetic lock is installed, we recommend setting multiple pulses for the lock correct and long functioning. These settings will help the locks work correctly and for a long time, especially mechanical as it might break if the voltage is applied to it for too long. |
- keep the lock open or not if SIP registration is lost. It is necessary to set no SIP registration time for this parameter.
Open lock
In this section, you can remotely open lock #1 or lock #2 (when using SH-42) by clicking the corresponding button.
Additional settings
Here you can:
- set the Floor number for further features that work only with the elevator control module EVRC-IP;
- enable/disable features of sending the elevator to the indicated floor number when the lock is open using an identifier or from the monitor;
Server manage access
Exit button
You can connect to a panel a button that will open the lock, e.g, for opening the door from the inside to exit the building. At the section, it is possible to activate/deactivate an exit button.
After enabling/disabling the button, do not forget to submit settings.
Door sensor input
It is possible to connect a door sensor or additional button to the door sensor input. In this section, you can enable/disable and configure their work.
After device installation and electric connection, you must do the following steps for correct work:
1. Log in to the entrance panel web interface. By default, the username is admin, and the password is 123456.
2. Open the Access management tab and find the Door sensor input section.
3. Enable sensor or button functioning by ticking the corresponding box.
4. Choose the appropriate input mode:
- door sensor mode is used to monitor the door state. If the door is not closed, after the expiration of the response time in Logs/Link logs will be shown that the door is open;
- door entry button mode is recommended when the connected button is used as an additional, remote from the panel, entry button;
5. If you use Door sensor mode, set the Response time after which the mode will be activated.
6. For the Door sensor, you can enable the option to resend a trigger message to Link logs and set the delay time before resending.
7. Submit settings.
Also, you can check and update the current door sensor input status (open/closed).