For correct device functioning, you must enter information about its logical address. The logical address is used to automatically synchronize and search for other devices in the network and is also necessary to provide a connection between them (for more information about logical address formation find here, see Logical addresses formation and setting). If you use the BAS-IP Link server we recommend configuring address settings remotely using the Link (via MQTT protocol) and then sending them to a device. 

You must enter the following data about the device location:

...

The SIP settings are required for the monitor to work via the SIP protocol. If you use the BAS-IP Link server we recommend configuring SIP settings remotely using the Link (via MQTT protocol) and then sending them to the device. 

Step-by-step guide For more info on how to get SIP nubmers numbers and configure a monitor panel for SIP calls if you use a BAS-IP SIP server you can find here, refer to the Step-by-step guide.

To configure SIP calls for the monitor, you must enable device SIP registration and enter the following parameters: 

...

  • user SIP number;

  • password for the SIP number;

  • RTP data profile;

If the connection with the SIP server is lost, it will be automatically renewrenewed. You can set the re-registration interval (from 30-900 seconds) between attempts to renew the connection. 

...

In the menu, you can configure the DTMF code, entering which the lock will be opened. Code length is up to 4 characters. 

In the section, you can perform the following actions:

  • enable/disable opening the lock before answering a call (works via internal protocol);

  • set DTMF code for lock #1.

...

  • call to specified number: when the concierge button is pressed, a call will be made to the number you specified (via the P2P or SIP protocol). It can be the number of concierge , or any other device. The button for the call is in the navigation bar of the monitor main screen.
    To configure this mode, you must select it in the corresponding field, enter the number in P2P or SIP format, and submit settings. 

...

  • multiple-concierge call: call all concierge monitors (AM-02) that are in the same network via the internal protocol. The call is made in turn to each monitor after a specified period of time (by default in 5 sec), which you must indicate in the Call interval for each concierge field. The feature will work after saving the settings.

...

Here you can enable/disable the supply of the monitor alarm output with +12 Volts after receiving an incoming call. For example, a lamp can be connected to the monitor alarm output and during an incoming call, the lamp will light up. It will be as additional incoming call signallingsignaling, e.g., for people who is are hard of hearing.

You can configure the following settings: 

  • enable/disable an incoming call indication;

  • enable/disable the current supply turning off after answering a call;

  • set the duration of current  the current supply;

  • enable/disable current supply during a call and conversation.

...

Multicast paging

Multicast pagingdistributes datato multiple recipients.Using multicast, a device (monitor) can send data (e.g., notifications or calls) to a provided multicast IP address, which is then distributed to other devices subscribed to listening to the specified IP address.

For the feature operation, you must enable the multicast paging and provide an IP address that the monitor must listen to get notifications.

...