...
To add numbers you must:
Click the Add button.
Enter the number/(s) for the SOS call in the corresponding format in the URL field.
Info |
---|
Number format for calls via P2P:
Number format for calls via SIP:
For correct functioning, the The SIP numbers must be registered with the same SIP server for correct functioning. |
Submit settings.
...
You can also enable the Use as concierge number feature and when pressing the concierge button, the call will be made to the numbers specified in this section. And, when the sensor is triggered (which works in the SOS call mode), a regular call will be made to the concierge monitor (AM-02).
...
In the Current security scenario field, you can check the current state of the alarm and enable the desired scenario.
...
You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify peculiarities and configure the operation of each sensor separately.
Note |
---|
Sensors Sensor setting is only available on the main monitor (with 0 device number). |
...
sensor No.;
sensor type:
normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors;
emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);
24-hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke, and heating sensors.
sensor operation mode (cases for triggering a sensor):
3C is activated by any change in the position of the contacts;
NO is for the normally open sensor, activated when the contacts are closed;
NC is for the normally closed sensor, activated when the contacts are opened;
bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;
call is for making a SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.
activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24-hour sensor type);
Info |
---|
The delay time is not summed with the alarm scene activation time. |
sensor name (type) selection for additional information when triggered. There are such available options as smoke, gas, PIR, door, window, panic, and flood.
...
Tip |
---|
To disable the alarm, enter the administrator password on the device. The default password is 123456. |
Logs
A monitor during a call automatically takes a photo of the caller on the 3rd second after the conversation starts. This photo is saved to the monitor memory and can be viewed in the Call records.
In this section, you can enable or disable the saving of these photos in monitor memory.
...