Select "Basic" to access the basic network settings:Image Removed

...

DHCP: Enable automatic receiving of the network settings.

Static IP Address: Enable manual mode for specifying network settings.

IP address: The IP address of the outdoor panel.

Subnet Mask: Subnet mask.

Default Gateway: The default gateway.

DNS1: The primary DNS server address.

DNS2: The secondary DNS server address.

Advanced

Select “Advanced” to access the advanced network settings:Image Removed

...

Local RTP

Starting RTP Port: The minimum value of the RTP port range (1024 –65535).

Maximum RTP port: The maximum value of the RTP port range (1024 – 65535).

SNMP

Status: Enable/disable the SNMP device control protocol.
Port: Used port (1024 – 65535).
Trusted IP: List of trusted IP addresses.

VLAN

Port Status: Enable/disable VLAN support.

VID: The VLAN identifier (1 – 4094).

Priority: VLAN priority (0 – 7, where 0 is the lowest priority).Image Removed

...

Status: Enable/disable of client’s TR-069.

Version: Used protocol version.

ACS URL: The address of ACS server. The panel will send messages about its status to this address.

Username: The username for authentication on ACS.

Password: The client password for authentication on ACS.

Periodically Informing: Turning on / off periodic information about the status.

Periodic interval: Interval of periodically informing (3 - 24 × 3600 s).

CPE URL: An address of Common Platform Enumeration. ACS TR-069 will manage the device at this address.

Username: CPE Username for authentication and follow up receiving of incoming requests.

Password: CPE user password for authentication and follow up receiving of incoming requests.

SOAP - "Simple object access protocol"; XML-based specification to execute the application functions.

CPE - equipment for customer premises or controlled device; include integrated gateways (IGD), network boxes (STB), network storage (NAS), etc.

ACS - Auto-Configuration Server, performs CPE management. Generally, controlled by the provider and connected to their operating or billing support systems (OSS / BSS). A data model is a set of objects, defined to manage a particular type of CPE.

The basic commands for controlling the panel using the TR-069 protocol are presented in the List of commands page.