Surface mounting

1. Make a hole in the wall of the following sizes 70X65X50 mm. It will serve for placing of all cable connections.

Image Removed

2. Attach the wall-mounting bracket to wall and make marks exactly where the holes need to be drilled.Image Removed

3. Make holes using an electric drill according to the made marks. Use drill bit with a diameter of not more than 5 mm.

Image Removed

4. Insert the dowels in previously made holes and hammer them.

Image Removed

5. Fix a wall-mounting bracket into the wall, using ST4X20 screws.

Image Removed

6. Install a protective cover and sealing ring as shown in figure.Image Removed

7. Make a connection of all wires and connect the sealing ring with protective shroud as shown in figure.Image Removed

8. Install the protective cover with M3X5 screws as shown in figure.Image Removed

9. Install the panel in the bracket for the wall mounting and fix it using M2.5X6.5 screws.

Image Removed

10. Installation completed.

Image Removed

Flush mounting

1. Make a hole in the wall of the following sizes 163.8 x 110.1 x 65 mm. It will serve for placing of bracket for flush mounting and all cable connections.Image Removed

2. Install the bracket into ready hole and make marks for subsequent bracket mounting.Image Removed

3. Make holes using an electric drill according to the made marks. Use a drill bit with a diameter of not more than 5 mm.Image Removed

4. Insert the dowels in previously made holes and hammer them.

Image Removed

5. Fix the flush-mounting bracket into the wall, using the ST4x20 screws.

Image Removed

6. To achieve maximum fixation, it is necessary to seal the gap between the wall and bracket using cement or other, not aggressive to metal mixture.

Image Removed

7. Insert the built-in box into the bracket and fix it using M4X10 screws.Image Removed

8. Install a protective cover and sealing ring as shown in figure.Image Removed

9. Make a connection of all wires and connect the sealing ring with protective shroud as shown in figure.Image Removed

10. Install the protective cover with M3X5 screws as shown in figure.

Image Removed

11. Install the panel in place and fix it with M2.5X6.5 screws using Allen key as shown in figure.

Image Removed

12. Installation completed.Image Removed