You can use this menu to set general control parameters of the access control system, access rules, and identifiers.
...
In this section, you can select the following parameters:
Wiegand Wiegand type for a card reader. Wiegand-26, Wiegand-34, and Wiegand-58 types are available for work.
identifier representation systems. All identifiers can be displayed in Decimal and HEX numeral systems.
...
There is a multifactor authorization feature in panel settings. In addition to the normal operation of identifiers, you can enable the mandatory use of several identifiers to open the lock/s. For example, the user must first bring the card to the reader and then show a QR code to get access.
Widget Connector | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
In this section, you can enable the necessary access mode. Two options are available:
...
Some BAS-IP panels have an inbuilt Wiegand input and output. In this case, the Wiegand version is displayed in the Dashboard tab. Otherwise, you can use an SH-12 module to connect an external controller via the Wiegand interface.
...
Info |
---|
If you enable the 3D mode on a panel without a 3D sensor, the software mode will be activated instead. |
6. Submit settings.
Also, you can turn on/off automatic face recognition when motion is detected. When a person approaches a panel (at a distance of up to 50 cm) motion sensor becomes active, and a panel will exit standby mode and turn on the face recognition feature.
...
QR recognition
QR codes also can be used as identifiers. Here you can enable/disable QR code recognition in general and when motion is detected (at a distance up to 50 cm motion sensor becomes active, and a panel will turn on the QR recognition).
...
Face/QR recognition audio prompt
...