Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

If you have more than 1 entrance panel with the same logical address, you need to specify their device numbers, starting from 1 to 9.

...

Panel
panelIconIdatlassian-light_bulb_on1f4a1
panelIcon:light_bulb_on:
panelIconText:light_bulb_on:💡
bgColor#E6FCFF

Note:

To make a call between the panel and the indoor monitor visitors must enter required information that depends on the chosen operation mode.

For correct functioning, the panel and the monitor must have the same building and unit number in apartment settings. Also for monitors, you must indicate corresponding information about the floor, apartment, and device number.

If there are no such settings, you must make forwarding queues for apartments with IP addresses or SIP numbers of monitors.

Using Unit mode (according to the panel settings from the photo above), to call apartment No 1, located on the 1st floor of the 1st unit, visitors must enter 1. So, monitor with logical address (number) 0001-01-00-01 will be called. In this logical address, 0001 is Building No., 01 stands for Unit No., 00 is Floor No., and 01 is a number of apartment. Thus, the same logical address must be set in the monitor settings: building - 1, unit - 1, floor - 0, apartment - 1.

If Wall mode is set, to call apartment No 1, located on the 1st floor of the 1st unit, visitors must enter 1-1-1. With the No Unit option, 1-1 is enough to enter. 

 So, monitor with logical address (number) 0001-01-00-01 will be called. In this logical address, 0001 is Building No., 01 stands for Unit No., 00 is Floor No., and 01 is a number of apartment. Thus, the same logical address must be set in the monitor settings: building - 1, unit - 1, floor - 0, apartment - 1.

...

Step-by-step guide how to get SIP nubmers and configure a panel for SIP calls if you use BAS-IP SIP server you can find here.

To configure SIP calls for the panel, you must enable device SIP registration and enter the following parameters: 

...

  • enable/disable autoanswer of all incoming calls;

  • enable/disable automatic ending of call after opening a lock;

  • configure the number of digits required to trigger an automatic call (from 1 to 4 digits).

  • configure call max time in sec (up to 2 h period after which the panel automatically ends an outgoing call if there is no answer);

  • configure talk max time in sec (up to 24 h period after which the panel automatically ends the outgoing conversation).

...