Individual call panels summary table
Cameras viewing angle
Image sensor format
Output video resolution
Minimum illumination
Protection class
Temperature conditions
Power consumption
Available colors
Flush mounting, Wall mounting with BR-AV bracket
Flush mounting, Wall mounting with BR-AV2 bracket
Flush mounting
101×177×46 mm
Dimensions of the panel
Possibilities to activate the lock
From the monitor, by guest link, by QR code, by license plate, from the BAS-IP Intercom app, from the BAS-IP Link app, from the web interface
From the monitor, by guest link, by QR code, by card, by access code, by license plate, from the BAS-IP Intercom app, from the BAS-IP Link app, from the web interface
From the monitor, by guest link, by QR code, by card, by license plate, from the BAS-IP Intercom, the BAS-IP Link and the BAS-IP UKEY apps, from the web interface
From the monitor, by guest link, from the BAS-IP Intercom app, from the BAS-IP Link app, from the web interface
From the monitor, by guest link, by QR code, by license plate, from the BAS-IP Intercom app, from the BAS-IP Link app, from the web interface
Operating system
Integration with ACS
Additional features and functions
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Mechanical call button;
- Place for a text beside the call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- 2 operation modes: Wall and Unit;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Mechanical call button;
- Place for a text beside the call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Mechanical call button;
- Place for a text beside the call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch call button;
- Integration with Control4 and other various systems;
- Emergency stations: AV-02FDE can be used as a help point, and AV-02IDE is for info calls, AV-02IPD has a company logo;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Mechanical call button;
- Place for a text beside the call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch call button;
- Integration with Control4 and other various systems;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch call button;
- Tamper sensor;
- Integration with Control4 and other various systems;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch call button;
- Tamper sensor;
- Integration with Control4 and other various systems;
Cameras viewing angle
Image sensor format
Output video resolution
Minimum illumination
Protection class
Temperature conditions
Power consumption
6.5 W, in standby – 4 W
Available colors
Dimensions of the panel
80×165×27 mm
Possibilities to activate the lock
Operating system
Integration with ACS
Output Wiegand-26, 32, 34, 37, 40, 42, 56, 58, 64; Input Wiegand-26, 34, 58
Additional features and functions
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Mechanical call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Rescue service and Help station features for quick emergency communication;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Mechanical call button;
- Tamper sensor;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch-free call button;
- Tamper sensor;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Touch-free call button;
- Tamper sensor;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Piezoelectric call button;
- Integration with Control4 and other various systems;
- SIP, P2P protocols support;
- Setting the lock opening time, delay before opening, DTMF values, automatic call acceptance, access codes;
- Compatible with the elevator module to send the elevator to the floor;
- Integration with Kone and other various systems;
- Calls to the concierge using a specified number;
- Support of up to 9899 subscribers via internal protocol;
- Calls forwarding via internal protocol, SIP or P2P;
- Creation of flexible access rules, limitation of validity period and number of passes for identifiers;
- Face Recognition configuration (3 similarity level and operation modes are available)
- Multifactor authorization;
- Customization of sound notifications;
- Support of the Link software;
- Server-based access control (Link or user server);
- Events log with actions done the panel;
- Sending e-mail notifications when selected events occur;
- Sending photos from the camera to the Link server;
- Syslog history;
- Settings backup and restoration;
- Software update from BAS-IP or custom server;
- Connection of 1-2 locks (via SH-42 module) to the panel;
- Exit button connection;
- Door sensor connection;
- Proximity Sensor;
- Tamper sensor;
- Piezoelectric call button;
- Backlight indication of a successful QR code or Face ID reading;