Table of Contents |
---|
...
sync code between monitors.
...
SIP
...
SIP
Widget Connector | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
The SIP settings are required for the monitor to work via the SIP protocol. To configure SIP calls, you must enable device SIP registration and enter the following parameters:
...
You can enable the auto re-registration to renew the lost connection with the SIP server and enter the re-registration interval (from 5-600 seconds). The feature is recommended to use in networks with an unstable Internet connection. If necessary, you can re-register the device manually by clicking the appropriate button.
...
DTMF settings
Widget Connector | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
In the menu, you can configure the DTMF code, entering which the lock will be opened. Code length is up to 4 characters.
In the section, you can:
enable/disable opening the lock before answering a call;
set DTMF code for lock #1.
...
enabling/disabling all incoming calls autoanswer;
enabling/disabling auto hung up after pressing the Open button during a call;
setting the delay time after pressing the Open button before opening the lock;
speaker volume adjustment during a conversation (talk volume);
general volume adjustment;
setting the conversation maximum time.
...
Call forwarding
Widget Connector | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
With this feature, you can connect up to 4 devices that will receive calls simultaneously with a call to the internal monitor.
...
Here you can enable/disable the supply of the monitor alarm output with +12 Volts ≤0,35A after receiving an incoming call. For example, a lamp can be connected to the monitor alarm output and during an incoming call the lamp will light up.
...