Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. The SW-02 converter has two interfaces: the LAN interface can be connected to the Internet, and the other interface is connected to a 2-wire system.

  2. The panel is connected to a two-wire system through the SW-02 converter on one side and to the local network on the other (it is also possible to connect the patch cord directly to the internal monitor).

  3. Connect the 48 V DC power supply to the SW-02 to provide power to the entire system, including the internal monitor (converters and switches support power transmission over PoE IEEE 802.3 af and at).

...

  • Power: The red LED is always on;

  • Two-wire connection: if the green LED is always on, it means that 2Wire Link mode is active. If the LED blinks slowly, it means the 2Wire Unlink mode is active;

  • LAN: green LED - Ethernet connection indicator. When the module transmits or receives data via Ethernet, the LED flashes with a period of for 250 ms.

Typical schemes for connecting system components 

When using this system, the connection of internal monitors can be carried out both on the same local network and using two-wire wiring.

Widget Connector
overlayyoutube
_templatecom/atlassian/confluence/extra/widgetconnector/templates/youtube.

...

vm
width750px
urlhttps://www.youtube.com/watch?v=D9ENPjBpM6c
height450px

A system with the individual panel

...

...

A system with a multi-apartment panel

...

...