Сonnection of an electromagnetic lock and an exit button connected from the entrance panel, using the controlled output Lock on the panel 


Сonnection of an electromechanical lock and an exit button connected from the entrance panel, using the controlled output Lock on the panel 


Сonnection using two electromagnetic locks and two exit buttons, when connected to the panel via RS485 as a control interface 


Сonnection using two electromechanical locks and two exit buttons, when connected to the panel via RS485 as a control interface 


Opening delay time (for 8-pin module)


The delay module is equipped with a trimmer, which is responsible for the response time of the relay. This is the time at which the relays will switch from one position to another when the opening signal to them is received via the RS-485 interface, the Lock input, and the exit buttons are pressed.

The use of electromagnetic locks

When connecting electromagnetic locks, the trimming resistor needs to be rotated to the right, and adjust the delay time in the range of 4 to 8 seconds. If you need to use other values, this time can
set more or less recommended values, but not less than 2 seconds.

The use of electromechanical locks

When connecting electromechanical locks, the trimmer must be turned to the left, and the delay time is adjusted in the range of 0.5 to 1 second. If necessary, the time can be slightly increased, but it is absolutely not recommended to set this time for more than 2 seconds!

Before mounting the reader, it is necessary to provide a hole or recess in the wall with dimensions 96×152×46 mm (for flush mounting). Dimensions of the bracket (flush box) = 94×151×45 mm. It is also necessary to provide for the supply of power cable, add. modules and local network.