Access settings
You can open basic settings from a panel or from a web interface. To enter the system settings, you must open the Pincode menu, enter the password for the settings menu (by default, it is *123*) and press the Call button. To go to the necessary menu, you need to press its icon.
In this menu, you can set:
lock open timeout is a period (1-300 sec) during which relay contacts will be closed or open (depending on the lock type), and a lock will stay open;
lock open delay is a period (1-300 sec) after which relay contacts will close or open after sending a signal to open a lock;
floor number (Elev Refer) where the panel is installed for further lift control module EVRC-IP use (optional);
password (no more than 8 characters) is a general code entered on a panel keypad to open a lock. The default password is 0000. Open the Pincode menu to enter an access code. Press the Call button after entering the code to confirm it.