Electrical connection
After verifying the device completeness, you can proceed to the monitor connection.
For connection you need:
an Ethernet UTP CAT5 or higher cable connected to a network switch/router;
The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.
power supply at + 12V, 2 Amps;Â
wires must be brought for connecting the lock and additional modules (optional).Â
Here are typical connection schemes:
- 1 Connection using the siren output as a controlled output with an external additional relay, to control devices or any other load with high power consumptionÂ
- 2 Connection using various types of buttons connected to alarm loops, and using them as bell buttonsÂ
- 3 Connection of security alarm sensors with NC (normally closed) contact typesÂ
- 4 Connection of security alarm sensors with NO (normally open) contact typesÂ
- 5 Connection of security alarm sensors with NC (normally closed) contact types using SH-16 module
- 6 Connection of security alarm sensors with NO (normally open) contact types using SH-16 module