Electrical connection

After verifying whether a device is complete, you can switch to the connection step.

For connection you will need:

  • an Ethernet UTP CAT5 or higher cable connected to a network switch/router;

The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.

  • power supply at + 12V, 2 Amps, if there is no PoE.; 

  • wires must be brought for connecting the lock and additional modules (optional). 

You can connect any type of electromechanical or electromagnetic lock for which the switched current does not exceed 1 Amps.

The following are typical connection schemes of all elements to the entrance panel:

Connection scheme of electromechanical lock using external power supply for panel and the lock.

1 (1).jpg

Connection scheme of electromagnetic lock using external power supply for panel and the lock.

 

2.png