Panel
In the tab, you configure settings for apartment, device, calls, and SIP calls.
Apartment Settings
For correct panel functioning, you must enter information about its logical address (for more information, see Logical addresses formation and setting):
panel operation mode
building number
unit number
floor number
apartment number
device number
If you have more than 1 entrance panel with the same logical address, you need to specify their device numbers, starting from 1 to 9.
Note:
The individual entrance panel is directly connected to the monitor. For correct functioning, the panel and the monitor must have the same building, unit, floor, and apartment number in apartment settings. Also for monitors, you must indicate their device numbers.
According to the panel settings from the photo above, the monitor with logical address (number) 0001-01-11-11 will be called. In this logical address, 0001 is a Building No., 01 stands for Unit No., 11 is a Floor No., and 11 is a number of apartment. Thus, the same logical address must be set in the monitor settings: building - 1, unit - 1, floor - 11, apartment - 11.
If there are no such settings, you must make forwarding queues for apartments with IP addresses or SIP numbers of monitors.
SIP settings
These settings are required for the correct work of calls via SIP protocol. If you use the BAS-IP Link server we recommend configuring SIP settings remotely using the Link (via MQTT protocol) and then sending them to the device.Â
For more info on how to get SIP numbers and configure a panel for SIP calls if you use a BAS-IP SIP server, refer to the Step-by-step guide.
To configure SIP calls for the panel, you must enable device SIP registration and enter the following parameters:Â
SIP server proxy that can be represented by both an IP address and a domain name
Data format:
Before the proxy address, you must enter "sip:", e.g. sip:gb.sip.bas-ip.com. A full list of BAS-IP servers for each country is available here.Â
If you use a third-party SIP server, you can also indicate a non-standard port in the format:Â
sip:gb.sip.bas-ip.com:1506 where gb.sip.bas-ip.com is a SIP server proxy, 1506 is a non-standard port.
SIP server address that can be represented by both an IP address and a domain name, e.g. gb.sip.bas-ip.com
server STUN IP address. For example, stun.l.google.com
port of the STUN server
user SIP number (up to 20 characters)
SIP user ID (optional)
password for SIP number (up to 20 characters)
transport type: UDP/TCP/TLS
If the connection with the SIP server is lost, it will be automatically renewed. You can set the re-registration interval (30-900 seconds) between attempts to renew the connection.Â
Call settings
At this part, you can perform the following actions:
enable/disable a call to the specified number when pressing the button connected to the door sensor input (Call button mode must be set).
indicate the direction (number) to which the call will be made when pressing the connected call button.Â
configure call max time (10-120 sec after which the panel automatically ends an outgoing call if there is no answer).
configure talk max time (10-300 sec after which the panel automatically ends the outgoing conversation).
enable/disable the end of a call by pressing the button on the panel.
enable/disable the end of outgoing calls when (connected to the panel) the exit button is triggered (e.g., by the concierge).
Device settings
In this section, you can configure the following parameters:
preferred video quality (resolution) (640Ń 480/1280Ń 720/1920x1080 (optional))
preferred RTP data profile
the volume level of a panel speaker
RTSP username (login to get access to a panel RTSP stream)
RTSP password (password to get access to a panel RTSP stream)
enable/disable audio for RTSP stream
enable/disable a proximity sensor for the panel automatic turning on the keyboard backlight and face recognition feature when motion is detected at a distance of 50 cm
select the appropriate proximity sensor mode:Â
all-time mode: the sensor is active all the time and triggered when motion is detected at a distance of 50 cm
adaptive mode (appropriate when the panel is installed in front of a wall or an object): the sensor gets used to a constant object in front of it and does not react to it, but only triggers when there is movement
enable/disable connected to the panel temperature sensor. During an outgoing call, the panel will take the temperature of the person in front of the panel and display it on the called person internal monitor during the call/talk