Mechanical mounting

AV-08FB

Before mounting the entrance panel, a hole or recess in the wall with dimensions of 111 х 185 х 60 mm
(for flush mounting) must be provided.

It is also necessary to provide supply of a power cable, additional modules and the local network.

The hole at the bottom is designed to drain the water. Do not intentionally close it. Also it is necessary to make a drain for water at the bottom of the niche which will serve to divert water out.

Flush mounting

image-20250102-114025.png

Surface mounting (with BR-AV8)

image-20250102-114157.png

Dimensions 

AV-08FBL/AV-08FBIL

Before mounting the entrance panel, a hole or recess in the wall with dimensions of 116x198х58 mm
(for flush mounting) must be provided.

It is also necessary to provide supply of a power cable, additional modules and the local network.

The hole at the bottom is designed to drain the water. Do not intentionally close it. Also it is necessary to make a drain for water at the bottom of the niche which will serve to divert water out.

Flush mounting

Surface mounting (with BR-AV8FBL)

Dimensions