Electrical connection
After verifying whether a device is complete, you can switch to the connection step.
For connection you will need:
an Ethernet UTP CAT5 or higher cable connected to a network switch/router;
The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.
power supply at + 12V, 2 Amps;
wires must be brought for connecting the lock and additional modules (optional).
You can connect any type of electromechanical or electromagnetic lock for which the switched current does not exceed 5 Amps.
The following are typical connection schemes of all elements to the entrance panel:
- 1 Connection using an external power supply and an electromagnetic lock
- 2 Connection using an external power supply and an electromechanical lock
- 3 Connection using an uninterruptible power supply unit and an electromagnetic lock
- 4 Connection using an uninterruptible power supply unit and an electromechanical lock
- 5 Connecting an MR-03KP reader via SH-12
Connection using an external power supply and an electromagnetic lock
Connection using an external power supply and an electromechanical lock
Connection using an uninterruptible power supply unit and an electromagnetic lock
Connection using an uninterruptible power supply unit and an electromechanical lock
Connecting an MR-03KP reader via SH-12
The MR-03KP keypad reader can be connected to the panel through the SH-12 interface module.
In this configuration:
the MR-03KP reader is connected to the SH-12 Wiegand Input;
SH-12 communicates with the panel through the RS-485 interface;
identifier data received by the reader is transferred to the panel via SH-12.
For detailed wiring instructions, see the SH-12 documentation.
Connection diagram: see the MR-03KP Electrical connection section.