Zone settings
You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify peculiarities and configure the operation of each sensor separately.
These settings are also available in the web interface.
The sensor setting is only available on the main monitor (with 0 device number).
The table with sensor settings consists of the following parameters:
sensor No.;
sensor type:Â
normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors;Â
emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);
24 hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke and heating sensors.
sensor operation mode (cases for triggering a sensor):Â
3C is activated by any change in the position of the contacts;
NO is for the normally open sensor, activated when the contacts are closed;
NC is for the normally closed sensor, activated when the contacts are opened;
Bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;
SOS call is for making an SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.
activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24 hour sensor type);Â
The delay time is not summed with the alarm scene activation time.
sensor name (type) selection for additional information when triggered. There are options as smoke, gas, PIR, door, window, panic, flood. Â
To disable the alarm, enter the administrator password on the device. The default password is 123456.