Security

The Security tab is for IP cameras and sensors configuration.

SOS monitors 

In this section, you can enter numbers for an emergency call when sensors functioning in the SOS call mode are triggered.

The Total field displays the number of added directions for a call.

To add numbers you must: 

  1. Click the Add button.

  2. Enter the number(s) for the SOS call in the corresponding format in the URL field.

Number format for calls via P2P: 

  • sip:1@192.168.1.65, where 1 is the desired number to be displayed for the callee, 192.168.1.65 is the IP address of the callee SIP client (if you use a softphone, the IP address of a device where the softphone is installed);

Number format for calls via SIP:

  • sip:5588@us.sip.bas-ip.com, where 5588 is the callee SIP number, фтв us.sip.bas-ip.com is the address of the SIP server, which can be either the IP address or domain name.

The SIP numbers must be registered with the same SIP server for correct functioning.

  1. Submit settings.  

You can also enable the Use as concierge number feature and when pressing the concierge button, the call will be made to the numbers specified in this section. And, when the sensor is triggered (which works in the SOS call mode), a regular call will be made to the concierge monitor (AM-02).

IP cameras 

In this section, you can add up to 10 IP cameras for their stream monitoring from the monitor. The Total field displays the number of added IP cameras.

How to add an IP camera via the web interface

  1. Open the Security tab and find the IP cameras section.

  2. Click Add. 

  3. Enter the name of the camera.

  4. Enter the RTSP URL of the camera stream. It is usually indicated in the installation instructions with the camera.

Example of the URL for RTSP stream:

rtsp://admin:123456@192.168.1.87:8554/ch01 

It includes the username (admin), user password (123456),  panel IP (192.168.1.87); a number of a camera access port (8554); channel number (ch01).

  1. After entering the required data, click Submit.

Security scenes settings 

With this section, you can set sensors that will be triggered in a corresponding scene. You can find the connection scheme of the sensors on the Electrical connection page.

There are 3 available scenes (Out, Home, Sleep) for various occasions. To configure their operation, select which sensors should be enabled/disabled for each scene.

The scene setting is only available on the main monitor (with 0 device number).

Delay(s) (from 0 to 300 sec) is the time after which the monitor will switch to security mode and activate the necessary scene.

In the Current security scenario field, you can check the current state of the alarm and enable the desired scenario.

When a sensor is triggered, an alarm signal will be sent to the main and all synchronized monitors. 

Security sensors settings 

You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify peculiarities and configure the operation of each sensor separately.

The table with sensor settings consists of the following parameters:

  • sensor No.;

  • sensor type: 

    • normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors; 

    • emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);

    • 24-hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke, and heating sensors.

  • sensor operation mode (cases for triggering a sensor): 

    • 3C is activated by any change in the position of the contacts;

    • NO is for the normally open sensor, activated when the contacts are closed;

    • NC is for the normally closed sensor, activated when the contacts are opened;

    • bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;

    • call is for making a SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.

  • activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24-hour sensor type); 

  • sensor name (type) selection for additional information when triggered. There are such available options as smoke, gas, PIR, door, window, panic, and flood.   

Logs

A monitor during a call automatically takes a photo of the caller on the 3rd second after the conversation starts. This photo is saved to the monitor memory and can be viewed in the Call records.

In this section, you can enable or disable the saving of these photos in monitor memory.

 

Related pages