Security

The Security tab is for IP cameras and sensors configuration.

SOS monitors 

In this section, you can enter numbers for an emergency call when sensors functioning in the SOS call mode are triggered.

The Total field displays the number of added directions for a call.

To add numbers you must: 

  1. Click the Add button.

  2. Enter number/s for SOS call in the corresponding format in the URL field.

Number format for calls via P2P: 

  • sip:1@192.168.1.65, where 1 is the desired number to be displayed for the callee, 192.168.1.65 is the IP address of the callee SIP client (if you use a softphone, the IP address of a device where the softphone is installed);

Number format for calls via SIP:

For correct functioning, the SIP numbers must be registered with the same SIP server.

  1. Submit settings.  

You can also enable the Use as concierge number feature and when pressing the concierge button, the call will be made to the numbers specified in this section. And, when the sensor is triggered (which works in the SOS call mode), a regular call will be made to the concierge monitor (AM-02).

If you enable use as concierge feature, then by long pressing the Concierge button, a normal (not SOS) call will be made. 

Security scenes settings 

With this section, you can set sensors that will be triggered in a corresponding scene. You can find the connection scheme of the sensors on the Electrical connection page.

There are 3 available scenes (Out, Home, Sleep) for various occasions. To configure their operation, select which sensors should be enabled/disabled for each scene.

Delay(s) (from 0 to 300 sec) is the time after which the monitor will switch to security mode and activate the necessary scene.

In the Current security scenario field you can check the current state of the alarm and enable the desired scenario.

When a sensor is triggered, an alarm signal will be sent to the main and all synchronized monitors. 

You can disable the alarm in the web interface or by long pressing (3 s) thebutton.

Security sensors settings 

You can connect 4 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify peculiarities and configure the operation of each sensor separately.

Sensors setting is only available on the main monitor (with 0 device number).

The table with sensor settings consists of the following parameters:

  • sensor No.;

  • sensor type: 

    • normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors; 

    • emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);

    • 24 hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke, and heating sensors.

  • sensor operation mode (cases for triggering a sensor): 

    • 3C is activated by any change in the position of the contacts;

    • NO is for the normally open sensor, activated when the contacts are closed;

    • NC is for the normally closed sensor, activated when the contacts are opened;

    • bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;

    • call is for making a SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.

  • activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24 hour sensor type); 

  • sensor name (type) selection for additional information when triggered. There are options such as smoke, gas, PIR, door, window, panic, and flood.  Â