Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

In this tab, you have access to the monitor system settings.

Device language 


You can select the system language from the available ones:

  • English;
  • Russian;
  • Ukrainian;
  • Spanish;
  • Polish;
  • Hebrew;
  • Dutch;
  • Turkish.

System settings


 This section is necessary for saving and further using the system settings. Here you can:

  • make a copy of the monitor settings by clicking Backup Settings;
  • download photos were taken during incoming calls by clicking Backup photo;
  • reset all settings (except the IP address) to default;
  • delete call history from the monitor Recent tab by clicking Reset records;
  • upload previously downloaded backup in case the monitor update fails. Select the required file to upload in the corresponding field and restore the settings.

Firmware upgrade 


By default, the BAS-IP server is used for updates. You have several ways to update device firmware:

  • automatically: check for software updates and if it is released, click Update Firmware. The update process will take some time and in the end, the monitor will reboot several times. If there are no updates, information about the current firmware version will be provided;

  • manually: download the necessary firmware from the webpage, click Choose file and upload the downloaded file. Click Check file and then Update. The update process will take some time and in the end, the monitor will reboot several times.

You also can use a custom server (used in closed intercom networks) for firmware updates.

How to configure custom server use for firmware updates

  1. Log in to the device web interface. By default, the username is admin and the password is 123456.
  2. Go to the System tab>Firmware upgrade section. 
  3. Enable the use of a custom server.
  4. Enter the link to the server (with version.json and firmware files) in the URL field.
  5. Submit settings.

To update firmware from a custom server, you also must check for updates and click Update Software.

User Password 


In this tab, you can change the user password. To do it: 

  1. Enter the current (previous) password.
  2. Create a new password and enter it in the appropriate field.
  3. Confirm the new password by re-entering.
  4. Save changes.

Admin Password 


In this section, you can change the administrator password that is used to enter the web interface and monitor settings. To do it: 

  1. Enter the current (previous) password.
  2. Create a new password and enter it in the appropriate field.
  3. Confirm the new password by re-entering.
  4. Save changes.

Reboot 


Here is a button for a monitor soft reset.

  • No labels