In this tab, you have access to configure the operation of security scenes, sensors, and user and administrator passwords.

In this tab, you have access to configure the operation of security scenes, sensors, and user and administrator passwords.

Alarm scenes setting 

With this section, you can set sensors that will be triggered in a corresponding scene. You can find the connection scheme of the sensors on the Electrical connection page.

There are 3 available scenes (Out, Home, Sleep) for various occasions. To configure their operation, select which sensors should be enabled/disabled for each scene.

Activation time (from 0 to 300 sec) is the time after which the monitor will switch to security mode and activate the necessary scene.

When a sensor is triggered, an alarm signal will be sent to the main and all synchronized monitors. Also, in the corresponding section, you can set additional notifications in the form of a message or a call to a SIP device.

To disable the alarm, enter the user password. The default password is 1234.

Alarm zones setting 

You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify pecularities and configure the operation of each sensor separately.

The table with sensor settings consists of the following parameters:

  • sensor No.;

  • sensor type

    • normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors; 

    • emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);

    • 24 hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke and heating sensors.

  • sensor operation mode (cases for triggering a sensor): 

    • NO is for the normally open sensor, activated when the contacts are closed;

    • NC is for the normally closed sensor, activated when the contacts are opened;

    • 3C is activated by any change in the position of the contacts;

    • Bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone.

  • activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24 hour sensor type); 

The delay time is not summed with the alarm scene activation time.

  • sensor name (type) selection for additional information when triggered. There are such available options as smoke, gas, PIR, door, window, panic, flood, pull cord, bed mat.   

To disable the alarm, enter the user password. The default password is 1234.

Motion detection 

Motion detection is the feature of recording video from the specified camera when the motion sensor is triggered. You can enable/disable and configure the feature in this section and in the web interface.

The feature requires connected motion sensors (up to 4) and an SD card.

How to configure motion detection via the monitor

  1. Open the Security menu of the Monitor settings.

  2. Go to the Motion detection section.

  3. Enable the feature.

  4. Set the duration of the video recording in the Recording time field.

  5. Set time interval when the sensor will work.

If the start time of the sensor coincides with its end, the sensor will work around the clock (00:00-00:00).
If the normal sensor type is selected, then for this feature the sensor will work only when the alarm is turned on. The sensor will work 24 hours a day if 24-hour sensor mode is selected.

  1. Select one or more cameras (from the list of added IP cameras) for video recording in the Motion sensor 1 - Motion sensor 4 fields.

For correct functioning, the number of selected cameras must match the number of connected sensors.

  1. Save settings.

Notification will be displayed near the call icon on the main screen, and you can watch the recorded video in the corresponding section of the Call menu.

User password  

In this tab, you can change the user password. To do it: 

  1. Enter the current (previous) password.

  2. Create a new password and enter it in the appropriate field. The password can be up to 16 digits and contain all ASCII symbols (a-z, A-Z, 0-9 and a selection of punctuation marks).

  3. Confirm the new password by re-entering.

  4. Save changes.

Admin password 

In this section, you can change the administrator password that is used to enter the web interface and monitor settings. To do it: 

  1. Enter the current (previous) password.

  2. Create a new password and enter it in the appropriate field. The password can be up to 16 digits and contain all ASCII symbols (a-z, A-Z, 0-9 and a selection of punctuation marks).

  3. Confirm the new password by re-entering.

  4. Save changes.