select the ID of the alarm output relay on the camera that must be activated when the license plate is recognized (available for IP cameras).
set a timeout of for the relay activity (available for IP cameras).
mark that the panel that is used with an additional camera for license plate recognition (available for panels).
...
Device basic configurations can be done in the device web interface. And if they are done, there is no need to set them from the Link side. But if some of the following parameters are missed or required require corrections, so they, also, can be done in the corresponding sections. You must enable setting enable the setting section you want to send.
...
automatic forwarding settings is a feature of automatic creation of forward forwarding rules for apartment group user/s and sending them to device/s. If this feature is enabled, for all groups will be automatically created and applied virtual numbers. And when When adding a user that has a virtual number/s to a group, forwarding that includes all user numbers is automatically created. In addition, SIP and address settings are also automatically created and sent to the device.
But if there are troubles with them (e.g., logical addresses are already set for devices manually and do not match created on the server or the Link set and sent SIP settings for connecting to an external address, but internal is required, etc.), it is possible to set and sent the following settings to the device manually:SIP settings are required for calls via SIP protocol. For correct SIP functioning, you must:
enable SIP;
select SIP address type: server URL or server external IP address;
enter SIP server address (realm) that can be represented by both an IP address and a domain name, e.g. gb.sip.bas-ip.com;
enter SIP server proxy that can be represented by both an IP address and a domain name, e.g. sip:gb.sip.bas-ip.com. Before the proxy address, you must enter "sip:";
server STUN IP address, e.g., stun.l.google.com;
port of the STUN server, e.g., 19302;
SIP number (login);
password for the SIP number;
timeout for re-registration to renew the lost connection with the SIP server.
address settings that are required for device correct display in the intercom system and connecting between devices. If you are adding a panel, you must select panel operation mode (more details are here). Building No., Unit No., Floor No., Apartment No. and Device No. must be indicated depending on the device type.
for an elevator controller the following settings can be done:
enable/disable sending of settings on the device;
select available mode: Up (an elevator moves only in the upward direction), Down (movement is only in the downward direction), Up and down (both directions are available), Access by identifier (movement only to those floors that are available for the used identifier);
select relay type: COM-NO/COM-NC;
set the time during which the relay will be switched;
set lift release time (during which relay will be closed/opened) for identifier and for API call;
enable/disable the switching relay when turning on the device;
createthe number of available relays) and corresponding relays for a unit;
a list of floors (depending onenter Floor No. and Relay No. that connected to each floor at the controller;
endicate indicate whether the floor is public or not. Users will always have access to the public floor despite their identifier settings;
select apartments located on each floor;
...