You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify pecularities peculiarities  and configure the operation of each sensor separately.


Aura panel
tab1
styles{"header":{"backgroundColor":{"color":"#ebb5d1cf"},"icon":{"size":18,"name":"faExclamation","color":"#000"}},"headline":{"text":{"fontSize":14,"fontWeight":"bold","color":"#000","textAlign":"left","text":"Warning"}},"base":{"size":{"width":400,"height":150},"backgroundColor":{"color":"#fdcde5b8"},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.2)","x":0,"y":1,"blur":6,"spread":0},{"color":"rgba(0, 0, 0, 0.4)","x":0,"y":12,"blur":4,"spread":-10}]}},"body":{"text":{"color":"rgba(0, 0, 0, 0.75)","fontSize":14,"fontWeight":"normal","textAlign":"left"}}}
body

The sensor setting is only available on the main monitor (with 0 device number).


The table with sensor settings consists of the following parameters:

  • sensor No.;
  • sensor type
    • normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors; 
    • emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);
    • 24 hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke and heating sensors.
  • sensor operation mode (cases for triggering a sensor): 
    • 3C is activated by any change in the position of the contacts;
    • NO is for the normally open sensor, activated when the contacts are closed;
    • NC is for the normally closed sensor, activated when the contacts are opened;
    • Bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;
    • SOS call is for making a SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.
  • activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal sensor type); 

    Aura panel
    tab1
    styles{"body":{"text":{"color":"#02070e","textAlign":"left","fontWeight":"lighter","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#ffab0096","width":10,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
    body

    The delay time is not summed with the alarm scene activation time.


  • sensor name (type) selection for additional information when triggered. There are such available options as smoke, gas, PIR, door, window, panic, flood.   
Aura panel
tab1
styles{"body":{"text":{"color":"#02070e","textAlign":"left","fontWeight":"lighter","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#ffab0096","width":10,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body

To disable the alarm, enter the administrator password on the device. The default password is 123456.