The Security tab is for IP cameras and sensors configuration.
Table of Contents |
---|
SOS monitors
In this section, you can enter numbers for an emergency call when sensors functioning in the SOS call mode are triggered.
The Total field displays the number of added directions for a call.
To add numbers you must:
- Click the Add button.
Enter number/s for SOS call in the corresponding format in the URL field.
Aura panel tab 1 styles {"body":{"text":{"color":"#02070e","textAlign":"left","fontWeight":"lighter","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#ffab0096","width":10,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]},"size":{}}} body Number format for calls via P2P:
- sip:1@192.168.1.65, where 1 is the desired number to be displayed for the callee, 192.168.1.65 is the IP address of the callee SIP client (if you use a softphone, the IP address of a device where the softphone is installed);
Number format for calls via SIP:
- sip:5588@us.sip.bas-ip.com, where 5588 is the callee SIP number, us.sip.bas-ip.com is the address of the SIP server, which can be either the IP address or domain name.
For correct functioning, the SIP numbers must be registered with the same SIP server.
- Submit settings.
You can also enable the Use as concierge number feature and when pressing the concierge button, the call will be made to the numbers specified in this section. And, when the sensor is triggered (which works in the SOS call mode), a regular call will be made to the concierge monitor (AM-02).
If you enable use as concierge feature, then by long pressing the Concierge button, a normal (not SOS) call will be made.
Security scenes settings
Security sensors settings
You can connect 4 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify peculiarities and configure the operation of each sensor separately.
- sensor operation mode (cases for triggering a sensor):
- 3C is activated by any change in the position of the contacts;
- NO is for the normally open sensor, activated when the contacts are closed;
- NC is for the normally closed sensor, activated when the contacts are opened;
- bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;
- call is for making a SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.
activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24 hour sensor type);
Aura panel tab 1 styles {"body":{"text":{"color":"#02070e","textAlign":"left","fontWeight":"lighter","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#ffab0096","width":10,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}} body The delay time is not summed with the alarm scene activation time.
- sensor name (type) selection for additional information when triggered. There are options such as smoke, gas, PIR, door, window, panic, and flood.
Aura panel | ||||||
---|---|---|---|---|---|---|
| ||||||
You can disable the alarm in the web interface or by long pressing (3 s) thebutton. |