You can use this menu to set general control parameters of the access control system, access rulestime profiles, and identifiers.
Table of Contents |
---|
...
At this part, you can change the following information about:
master card. This card is used to add other cards to panel memory. Here you must specify the card number;
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
To add a master card if its number is unknown:
To add a user card using the master card:
The time between adding cards must not exceed 10 seconds. This method is convenient for mass and quick identifiers identifier adding. But However identifiers are not connected to the necessary apartment, so we recommend adding identifiers through the web interface. |
...
In this section, you can select the following parameters:
wiegand Wiegand type for a card reader. Wiegand-26, Wiegand-34, and Wiegand-58 types are available for work;
identifier representation systems. All identifiers can be displayed in Decimal and HEX numeral systems.
...
In this section, you can enable the necessary access mode. Two options are available:
normal mode is : basic access by one identifier that is linked to an apartment or user;
global mode: activates the use of several identifiers for all added users.
...
Log in to the device web interface. By default, the username is admin, and the password is 123456.
Go to Access management > Access mode.
Choose Global in the Mode field.
Select necessary identifier types that users must use to get access: QR code, Card, Access code, Ukey.
Submit settings.
...
At this part, you can configure the functioning of 1 or 2 (when using SH-42) locks. The following parameters can be configured:
lock open time is : a period (1-300 sec) during which relay contacts will be closed or open (depending on the lock type), and a lock will stay open;
lock open delay is : a period (0-300 sec) after which relay contacts will close or open after sending a signal to open a lock;
DTMF value for each lock or all locks. It is : a code (max length - 4 characters) after entering which the lock will open. By default, all entrance panels are set to receive # to unlock the 1st lock and 0 to unlock the 2nd one.
Info |
---|
This feature allows you to use non-standard DTMF symbols (#, *, and 0) to open locks. This solves the problem with usage #, *, and 0 symbols for other functions by third-party devices (for example, SIP phones often use these characters to forward or put a call on hold). In case of using a private SIP server, be sure to enable the RFC2833 mode for DTMF. |
impulse opening modeopening mode: one or multiple pulses. It is available to set pulse duration and time between pulses for multiple pulses mode.
...
In this section, you can remotely open lock #1 or lock #2 (when using SH-42) by clicking the corresponding button.
...
Additional settings
Here, you can configure the settings required for the interaction between the panel, indoor video entry phone, and EVRC-IP elevator control module:
...
enable/disable monitor secure mode is a feature of alarm deactivation on an indoor monitor when bringing an identifier (that is linked with the monitor) to the panel reader.
...
Note |
---|
Be aware, that that the EVRC-IP elevator control module must be connected and configured properly. All detailes details about the module you can find here. |
...
Wiegand controller
Some BAS-IP panel can be connected with panels have an inbuilt Wiegand input and output. In this case, the Wiegand version is displayed in the Dashboard tab. Otherwise, you can use an SH-12 module to connect an external controller via the Wiegand interface.
In the section, you can enable/disable playing custom sound and displaying a custom text when the lock is open.
You also can customize sound and text notifications for door opening by identifiers added to the controller.
...
manage Wiegand input and output.
The Wiegand input is used for a panel integration with an external controller and receiving values from the controller. To configure the input, complete the following steps:
Enable the input operation.
Select the preferred Wiegand type (the length of the received data).
Submit settings.
...
The Wiegand output is used for a panel integration with an external controller and sending identifiers received by the panel to the controller. To configure the output, you must complete the following steps:
Enable the output operation.
Select the output operation mode:
duplicate: a panel decides whether to grant access or not and simply copies identifier values to an external controller.
external access control: a panel only reads and sends identifier values to an external controller that decides whether to grant access or not.
Set the preferred Wiegand type (the length of the shared data).
Select the data type that the panel must send via the Wiegand output:
QR codes
face IDs
access codes
identifies received by an internal reader
identifies received by an external reader (connected to the Wiegand input)
Submit settings.
...
Server manage access
In this section, you can enable and configure working mode when all identifiers are not stored in a panel memory but on a server. When the identifier is brought to the reader, the panel will send a request to the server and wait for a response - to give access or not.
...
To configure this feature you must complete these steps:
Log in to the entrance panel web interface. By default, the username is admin, and the password is 123456.
Open the Access management tab and find the Server manage access section.
Enable the feature.
Click Use custom server and enter it. You can use the Link server.
Submit settings.
...
Also, you can turn on/off automatic face recognition when motion is detected. When a person approaches a panel (at a distance of up to 50 cm) motion sensor becomes active, and a panel will exit standby mode and turn on the face recognition feature.
...
It is possible to connect a door sensor or additional button to the door sensor input. In this section, you can enable/disable and configure their work.
Info |
---|
The door sensor input works only if the exit button is enabled in the Exit button section. |
After device installation and electric connection, you must do the following steps for correct work:
Log in to the entrance panel web interface. By default, the username is admin and the password is 123456.
Open the Access management tab and find the Door sensor input section.
Enable the sensor or button functioning by ticking the corresponding box.
Choose the appropriate input mode:
...