You can use this menu to set general control parameters of the access control system, access rules, and identifiers.

Table of Contents

Access management  

At In this part, you can change information about a master card. This card is used to add other cards to panel memory. Here you must specify the card number

...

. 

Panel
panelIconIdatlassian-light_bulb_on
panelIcon:light_bulb_on:
panelIconText:light_bulb_on:
bgColor#E6FCFF

To add a master card if its number is unknown: 

  1. Open the Access management tab of the panel wen web interface. 

  2. Enter 0 in the Master card field and submit changes.

  3. Bring the card to a panel reader and wait for the BEEP signal, which means that the master card has been successfully registered.

To add a user card using the master card: 

  1. Bring the card to a panel reader to switch to the adding user cards mode.

  2. Bring the user card to the reader. After reading the card, you will hear the BEEP signal, which means the successful registration of the card.

  3. Open the Identifiers tab in the web interface, where the added card will be displayed.

  4. Add missing information about the card and save changes.

The time between adding cards must not exceed 10 seconds. 

This method is convenient for mass and quick identifiers identifier adding. But However identifiers are not connected to the necessary apartment, so we recommend adding identifiers through the web interface.

...

In this section, you can select the following parameters

  • wiegand Wiegand type for a card reader. Wiegand-26, Wiegand-34, and Wiegand-58 types are available for work;.

  • identifier representation systems. All identifiers can be displayed in Decimal and HEX numeral systems.

...

There is a multifactor authorization feature in panel settings. In addition to the normal operation of identifiers, you can enable the mandatory use of several identifiers to open the lock/s. For example, the user must first bring the card to the reader and then show a QR code to get access.

Widget Connector
overlayyoutube
_templatecom/atlassian/confluence/extra/widgetconnector/templates/youtube.vm
width750px
urlhttps://www.youtube.com/watch?v=W8qI9zTso38
height350px

In this section, you can enable the necessary access mode. Two options are available:

  • normal mode is : basic access by one identifier that is linked to an apartment or user;.  

  • global mode: activates the use of several identifiers for all added users.  

...

  1. Log in to the device web interface. By default, the username is admin, and the password is 123456.

  2. Go to Access management > Access mode.

  3. Choose Global in the Mode field.

  4. Select necessary identifier types that users must use to get access: QR code, Card, Access code, Ukey, or Face ID (for panels with FB letters in their name). 

  5. Submit settings. 

...

At this part, you can configure the functioning of 1 or 2 (when using SH-42) locks. The following parameters can be configured: 

  • lock open time is a : period (1-300 sec) during which relay contacts will be closed or open (depending on the lock type), and a lock will stay open;.

  • lock open delay is a : period (0-300 sec) after which relay contacts will close or open after sending a signal to open a lock;.

  • DTMF value for each lock or all locks. It is : a code (max length - 4 characters) after entering which the lock will open. By default, all entrance panels are set to receive # to unlock the 1st lock and 0 to unlock the 2nd one.

...

  • set the Floor number where the entrance panel is installed. This parameter is required for all EVRC-IP features to work;.

  • enable/disable automatic identifier data sending to an EVRC-IP (required if EVRC-IP module works in the Access control mode);  .

  • enable/disable features of sending the elevator to the indicated floor number when the lock is open using an identifier;.

  • enable/disable features of sending the elevator to the indicated floor number when the lock is open from the monitor;.

  • enable/disable features of sending the elevator to the indicated floor number using a DTMF code on the monitor.   

...

  • enable/disable monitor secure mode is a feature of alarm deactivation on an indoor monitor when bringing an identifier (that is linked with the monitor) to the panel reader.

...

Note

Be aware, that  that the EVRC-IP elevator control module must be connected and configured properly. All detailes details about the module you can find here

...

Wiegand controller 

Some BAS-IP panel can be connected with panels have an inbuilt Wiegand input and output. In this case, the Wiegand version is displayed in the Dashboard tab. Otherwise, you can use an SH-12 module to connect an external controller via the Wiegand interface.

In the section, you can enable/disable playing custom sound and displaying a custom text when the lock is open. 

Follow the link to configure sound and text notifications for door opening by identifiers added to the Wiegand controller. 

...

manage Wiegand input and output. 

The Wiegand input is used for a panel integration with an external controller and receiving values from the controller. To configure the input, complete the following steps:

  1. Enable the input operation.

  2. Select the preferred Wiegand type (the length of the received data).

  3. Submit settings.

...

The Wiegand output is used for a panel integration with an external controller and sending identifiers received by the panel to the controller. To configure the output, you must complete the following steps:

  1. Enable the output operation.

  2. Select the output operation mode:

  • duplicate: a panel decides whether to grant access or not and simply copies identifier values to an external controller.

  • external access control: a panel only reads and sends identifier values to an external controller that decides whether to grant access or not.

  1. Set the preferred Wiegand type (the length of the shared data).

  2. Select the data type that the panel must send via the Wiegand output:

  • QR codes

  • face IDs

  • identifies received by an internal reader (available for AV-08FB and AV-08FBL)

  • identifies received by an external reader (connected to the Wiegand input)

  1. Submit settings.

...

Server manage access 

In this section, you can enable and configure working mode when all identifiers are not stored in a panel memory but on a server. When the identifier is brought to the reader, the panel will send sends a request to the server and wait waits for a response - to give access or not.

...

To configure this feature you must complete these steps

  1. Log in to the entrance panel web interface. By default, the username is admin, and the password is 123456.

  2. Open the Access management tab and find the Server manage access section.

  3. Enable the feature.

  4. Click Use custom server and enter it. You can use the Link server.

  5. Submit settings.

...

  • low: the minimal similarity is necessary for access (changes in appearance (glasses, beard, presence of a hat) will not be taken into account);.

  • normal: some changes in appearance are taken into account, but not detailed (recommended for homes and offices);.

  • high: the maximum similarity is necessary for access (recommended for high-security places).

...

  • software: the software recognition algorithm is used, and there is a possibility of giving access by photos;.

  • anti-spoofing: a more detailed software recognition algorithm is used to prevent access by photos;.

  • 3D (is available for panels with a built-in 3D sensor): detailed face recognition using IR sensors and building a face heat map to prevent spoofing.

Info

If you enable the 3D mode on a panel without a 3D sensor, the software mode will be activated instead.

6. Submit settings.

Also, you can turn on/off automatic face recognition when motion is detected. When a person approaches a panel (at a distance up to 50 cm) motion sensor becomes active, and a panel will exit standby mode and turn on the face recognition feature.

...

QR recognition 

QR codes also can be used as identifiers. Here you can enable/disable QR code recognition in general and when motion is detected (at a distance up to 50 cm motion sensor becomes active, and a panel will turn on the QR recognition).

...

.

...

Face/QR recognition audio prompt 

...

It is possible to connect a door sensor or additional button to the door sensor input. In this section, you can enable/disable and configure their work.

Info

The door sensor input works only if the exit button is enabled in the Exit button section.

After device installation and electric connection, you must do the following steps for correct work: 

  1. Log in to the entrance panel web interface. By default, the username is admin, and the password is 123456.

  2. Open the Access management tab and find the Door sensor input section.

  3. Enable the sensor or button functioning by ticking the corresponding box.

  4. Choose the appropriate input mode:

  • door sensor mode is used to monitor the door state. If the door is not closed, after the expiration of the response time in Logs/Syslog/Link logs/Email notifications will be shown that the door is open;.

  • door entry button mode is recommended when the connected button is used as an additional, remote from the panel, entry button;.

  • concierge call mode is appropriate when the connected button is used to call the concierge using the internal protocol.

  1. Set the Response time after which the mode will be is activated.

  2. For Door sensor and Door entry button modes, you can enable the option to resend a trigger message to Logs/Syslog/Link logs/Email notifications and set the delay time before resending.   

  3. Submit settings.

...