After checking the completeness of the device, you can proceed to the connection.

To connect you will need:

  • Ethernet cable UTP cat5 or higher connected to a network switch / router.

title
Info

Cable lenght recomendations

The maximum length of a UTP CAT5 cable segment must not exceed 100 meters, according to the IEEE 802.3 standard.

  • To connect the panel via PoE, you need to use a switch that works with 802.3 af support with a maximum power per port of no more than 15.4 watts.

Warning

When connecting the panel panel by PoE,it is prohibited to power the lock using panel's power. You must use a separate power supply, otherwise it may cause damage to the device.

  • Power supply at +12 Volt, 2 Ampere.

  • Wires must be brought for connecting the lock and additional modules (optional).

    Tip

    You can connect any type of electromechanical or electromagnetic lockĀ for which the switched current does not exceed 5 Amps.


Below is the designation of all contacts on the panel.Image Removed

Pin assignment on the outdoor panel:

...