Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

In the tab, you configure settings for apartment, device, calls, and SIP calls.

Apartment Settings 


For correct panel functioning, you must enter information about its logical address:

  • panel operation mode;
  • building number; 
  • unit number; 
  • floor number;
  • apartment number;
  • device number

SIP settings


These settings are required for the correct work of calls via SIP protocol. Step-by-step guide how to get SIP nubmers and configure a panel for SIP calls if you use BAS-IP SIP server you can find here.

To configure SIP calls for the panel, you must enable device SIP registration and enter the following parameters: 

  • SIP server proxy that can be represented by both an IP address and a domain name;
  • SIP server address that can be represented by both an IP address and a domain name;
  • port of the STUN server;
  • user SIP number (up to 20 characters); 
  • password for SIP number (up to 20 characters);
  • transport type: UDP/TCP/TLS. 

You can enable the auto re-registration to renew the lost connection with the SIP server and enter the re-registration interval (from 5-600 seconds). The feature is recommended to use in networks with an unstable Internet connection. If necessary, you can re-register the device manually by clicking the appropriate button.

Call settings 


At this part you can:

  • enable/disable a call to the specified number when pressing the connected to the door sensor input button (Call button mode must be set);
  • indicate the direction (number) to which the call will be made when pressing the connected call button; 
  • enable/disable autoanswer of all incoming calls;
  • enable/disable ending a call by pressing the button on the panel;
  • enable/disable automatic ending of call after opening a lock;
  • configure call max time in sec (up to 2 h period after which the panel automatically ends an outgoing call if there is no answer);
  • configure talk max time in sec (up to 24 h period after which the panel automatically ends the outgoing conversation).

Device settings


In this section you can: 

  • adjusts a volume level of a panel speaker;

Relay settings 


Here you can select the initial state of the panel relay when the device is turned on. If you select Switch when the device is turned on, so the relay will switch the position to the opposite. The relay will return to its original position after turning off the panel. The relay will not switch the position when the device is turned on and off if the corresponding mode is selected.  

The feature is good when you want/don't to keep the lock open or closed (if an electromagnetic lock is used) if there is no device power supply.  

  • No labels