You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify peculiarities and configure the operation of each sensor separately.

The table with sensor settings consists of the following parameters:

  • sensor No.;
  • sensor type
    • normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors; 
    • emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);
    • 24 hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke, and heating sensors.
  • sensor operation mode (cases for triggering a sensor): 
    • 3C is activated by any change in the position of the contacts;
    • NO is for the normally open sensor, activated when the contacts are closed;
    • NC is for the normally closed sensor, activated when the contacts are opened;
    • Bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone;
    • SOS call is for making an SOS call (to the number specified in the web interface or to the concierge) when the sensor contacts are closed.
  • activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24 hour sensor type); 

  • sensor name (type) selection for additional information when triggered. There are such available options as smoke, gas, PIR, door, window, panic, and flood.   