Device

In the tab, you configure settings for apartment, device, calls, and SIP calls.

Apartment Settings 

For correct panel functioning, you must enter information about its logical address:

  • panel operation mode;

Info about operation modes

There are 3 modes available, which are intended for certain working conditions:

Personal mode is recommended to set for correct work as a reader, i.e. to open lock(s). 

If the device is going to be used in combination with the EVRC-IP module, wall or global mode must be selected. If one of these modes is selected, the features of sending an elevator when opening the lock and pressing the button will be available.     

Wall mode is used when the device is installed on the perimeter of the object. 

Unit mode is required if the device is installed near the unit entrance

  • building number (for Unit and Personal modes only); 

  • unit number (for Unit and Personal modes only); 

  • floor number (for Personal mode only);

  • apartment number (for Personal mode only);

  • device number. 

If you have more than 1 entrance panel with the same logical address, you need to specify their device numbers, starting from 1 to 9.

For correct functioning, the reader and the monitor must have the same building, unit, floor, and apartment number in apartment settings.

According to the panel settings from the photo above, the monitor with the logical address (number) 0001-01-11-11 will be called. In this logical address, 0001 is Building No., 01 stands for Unit No., 11 is Floor No., and 11 is a number of apartment. Thus, the same logical address must be set in the monitor settings: building - 1, unit - 1, floor - 11, apartment - 11.

Device settings 

In this section you can adjusts a volume level of a panel speaker.

Relay settings 

Here you can select the initial state of the panel relay when the device is turned on. If you select Switch when the device is turned on, so the relay will switch the position to the opposite. The relay will return to its original position after turning off the panel. The relay will not switch the position when the device is turned on and off if the corresponding mode is selected.  

The feature is good when you want/don't to keep the lock open or closed (if an electromagnetic lock is used) if there is no device power supply. Â