Connection using the siren output as a controlled output with an external additional relay, to control devices or any other load with high power consumption Connection using various types of buttons connected to alarm loops, and using them as bell buttons Connection of security alarm sensors with NC (normally closed) contact types Connection of security alarm sensors with NO (normally open) contact types
AQ-07LW
Wiring diagram using a two-wire switch Wiring diagram using a two-wire converter
AT-07, AT-07L, AT-07LT, AT-10, AT-10L
Connection using the siren output as a controlled output with an external additional relay, to control devices or any other load with high power consumption Connection using various types of buttons connected to alarm loops, and using them as bell buttons Connection of security alarm sensors with NC (normally closed) contact types Connection of security alarm sensors with NO (normally open) contact types
AZ-07L
Connection using the siren output as a controlled output with an external additional relay, to control devices or any other load with high power consumption Connection using various types of buttons connected to alarm loops, and using them as bell buttons Connection of security alarm sensors with NC (normally closed) contact types Connection of security alarm sensors with NO (normally open) contact types
AZ-07LL
Connection using the siren output as a controlled output with an external additional relay, to control devices or any other load with high power consumption Connection using various types of buttons connected to alarm loops, and using them as bell buttons Connection of security alarm sensors with NC (normally closed) contact types Connection of security alarm sensors with NO (normally open) contact types
AU-04LA, AU-04LAF, SP-03
Connection using the siren output as a controlled output with an external additional relay, to control devices or any other load with high power consumption Connection using various types of buttons connected to alarm loops, and using them as bell buttons Connection of security alarm sensors with NC (normally closed) contact types Connection of security alarm sensors with NO (normally open) contact types
AM-02
Connection using an external power supply Connection using power supply from PoE
Connection of security alarm sensors with NC (normally closed) contact types using SH-16 module
Connection of security alarm sensors with NO (normally open) contact types using SH-16 module