To make a call between a panel and an indoor video entry phone (monitor) by pressing the button of the required apartment or entering its number, the panel and the monitor must have the same building and unit number in apartment settings. Also for monitors, you must indicate corresponding information about the floor, apartment, and device number.
If there is no monitor, it is turned off or such settings are missing, you must make forward queues for apartments to redirect calls to IP addresses or SIP numbers.
Forward settings
Two forwarding modes are available:
- all at once: the call is made to all numbers simultaneously.
- one by one: the call is made to the numbers in turn with a 20 seconds delay.
Example of panel operation in combination with a digital two-wire system
We are required to call the apartment 27. When entering 27 value on the panel, it makes a call via internal protocol to the monitor in apartment 27. If there are no answer from the monitor, the panel refers to the forwarding table to check if there are any records for apartment 27.
Then there are several ways for the panel to act:
- if there is no record for apartment 27 or it is empty, the panel will end the call;
- if there is an laskomex:27 number, the panel will call the Laskomex handset with the No. 27;
- if for 27th apartment the SIP or P2P number is entered, e.g., sip:1346@us.sip.bas-ip.com, the panel will make a call to the specified number via SIP or P2P;
- if there are several numbers indicated, e.g., laskomex:25;sip:1346@us.sip.bas-ip.com, the panel will make a call first to the Laskomex handset with the 27th number , and then to the specified SIP number;