After checking the completeness of the device, you can proceed to the connection.
To connect you will need:
- Ethernet cable UTP cat5 or higher connected to a network switch / router.
Cable lenght recomendations
- To connect the panel via PoE, you need to use a switch that works with 802.3 af support with a maximum power per port of no more than 15.4 watts.
- Power supply at +12 Volt, 2 Ampere.
Wires must be brought for connecting the lock and additional modules (optional).
You can connect any type of electromechanical or electromagnetic lock for which the switched current does not exceed 5 Amps.
Below is the designation of all contacts on the panel.
Pin assignment on the outdoor panel:
GND: Ground.
12V: Power supply + 12 Volts.
485A: RS485 Data +.
485B: RS485 Data -.
DoorA-DoorE: Controlled inputs (dry contacts). It is possible to use for connecting the exit buttons and door sensors, and fire alarm sensors as well, if connected to the corresponding bus.
GNDA-GNDE: Ground for controlled inputs.
D0: Contact Data 0 for Wiegand.
D1: Contact Data 1 for Wiegand.
GND: Ground for Wiegand.
GND: Ground for locks.
R_A_NO: Normally open contact for 1 relay.
R_A_COM: Switchable contact for 1 relay.
R_A_NC: Normally closed contact for 1 relay.
R_B_NO: Normally open contact for 2 relay.
R_B_COM: Switchable contact for 2 relay.
R_B_NC: Normally closed contact for 2 relay.