Electrical connection

After verifying whether a device is complete, you can switch to the connection step.

For connection you will need the following components:

  • Ethernet UTP CAT5 or higher cable connected to a network switch/router.

The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.

  • Power supply at + 12V, 2 Amps. 

  • Wires must be brought to connect the lock and additional modules (optional). 

You can connect any type of electromechanical or electromagnetic lock for which the switched current does not exceed 5 Amps.

The following are typical connection schemes of all elements to the entrance panel:

Connection using an external power supply and an electromagnetic lock 

7-20220608-082214.jpg

Connection using an external power supply and an electromechanical lock

8-20220608-082235.jpg

Connection using an uninterruptible power supply unit and an electromagnetic lock

 

Connection using an uninterruptible power supply unit and an electromechanical lock