Table of Contents |
---|
Widget Connector | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
To make a call between a panel and an indoor video entry phone (monitor) by pressing the button of the required apartment or entering its number, the panel and the monitor must have the same building and unit number in apartment settings. Also for monitors, you must indicate corresponding information about the floor, apartment, and device number.
...
Note |
---|
For digital two-wire systems, it is obligatory to configure a forwarding queue for each apartment. |
...
During a call, the entrance panel checks its forwarding queue only when it fails to find any monitors according to the entered values of the building, unit, floor, and apartment. If you want to enable the Forwarding from the beginning (without searching the corresponding monitor via the internal protocol), you need to set different logical addresses for the panel and the monitor. For a detailed explanation of the correct logical address configuration, please refer to the Forwarding from the entrance panel article.
Forward settings
Two forwarding modes are available:
all at once: the call is made to all numbers simultaneously.
one by one: the call is made to the numbers in turn with a 20 seconds -second delay.
...
Warning |
---|
If you have an analog and IP device in the same queue, the All at once mode will impossible to do not work. |
How to make a new forward queue
Log in to the entrance panel web interface. By default, the username is admin, the password is 123456.
Open the Forward tab and click New Forward.
Enter your Apartment Number which consists of the floor and room number. For example, 223 indicates apartment 23 located on the 2nd floor. Entering this number on the panel the queue will work.
Enter the Forward Number (directions for call forwarding). You can add up to 8 numbers for forwarding. Calls can be made both via P2P and via the SIP protocol.
Info |
---|
Format for calls via P2P: Two formats for numbers are available:
Format for calls to SP-02 is:
Format for calls via SIP:
You can also use the short form and enter only the callee SIP number of the called device ("sip:" at the beginning and the SIP server address can be skipped). So, it is enough to enter 5588. For the forwarding correct function, the SIP numbers in one queue must be registered on the same SIP server. For example, forwarding will work for your SIP numbers registered on the us.sip.bas-ip.com server. Format for calling the handset of a digital two-wire system:
|
...
Example of panel operation in combination with a digital two-wire system
We are required to call the apartment 27. When entering the 27 value on the panel, it makes a call via internal protocol to the monitor in apartment 27. If there are no answer answers from the monitor, the panel refers to the forwarding table to check if there are any records for apartment 27.
...
if there is no record for apartment 27 or it is empty, the panel will end the call;
if there is an a laskomex:27 number, the panel will call the Laskomex handset with the No. 27;
if for the 27th apartment the SIP or P2P number is entered, e.g., sip:1346@us.sip.bas-ip.com, the panel will make a call to the specified number via SIP or P2P;
if there are several numbers indicated, e.g., laskomex:25;sip:1346@us.sip.bas-ip.com, the panel will make a call first to the Laskomex handset with the 27th number, and then to the specified SIP number;