Security settings
In this tab, you have access to configure the operation of security scenes, sensors, and user and administrator passwords.
Alarm scenes settingÂ
With this section, you can set sensors that will be triggered in a corresponding scene. You can find the connection scheme of the sensors on the Electrical connection page.
There are 3 available scenes (Out, Home, Sleep) for various occasions. To configure their operation, select which sensors should be enabled/disabled for each scene.
Activation time (from 0 to 300 sec)Â is the time after which the monitor will switch to security mode and activate the necessary scene.
When a sensor is triggered, an alarm signal will be sent to the main and all synchronized monitors. Also, in the corresponding section, you can set additional notifications in the form of a message or a call to a SIP device.
To disable the alarm, enter the user password. The default password is 1234.
Alarm zones settingÂ
You can connect 8 alarm sensors to the monitor. The number of sensors can be increased up to 16 using the SH-16 module. This menu allows you to specify pecularities and configure the operation of each sensor separately.
The table with sensor settings consists of the following parameters:
sensor No.;
sensor type:Â
normal: the sensor is activated only when the scene (for which it is enabled) is turned on. Typically this type is used for door and window sensors;Â
emergency: the sensor is active all the time, and a trigger notification is sent to the Management Software (no longer supported);
24 hour: the sensor is active all the time, regardless of the selected scene. This type can be selected for flood, gas, volume, smoke and heating sensors.
sensor operation mode (cases for triggering a sensor):Â
NO is for normally open sensor, activated when the contacts are closed;
NC is for normally closed sensor, activated when the contacts are opened;
3C is activated by any change in the position of the contacts;
Bell is for functioning in doorbell mode. When the contacts are closed, the monitor will start playing the incoming call ringtone.
activation delay time (from 0 to 60 sec) before the sensor is triggered (available when selecting a normal and 24 hour sensor type);Â
The delay time is not summed with the alarm scene activation time.
sensor name (type) selection for additional information when triggered. There are such available options as smoke, gas, PIR, door, window, panic, flood, pull cord, bed mat. Â
To disable the alarm, enter the user password. The default password is 1234.
User password Â
In this tab, you can change the user password. To do it:Â
Enter the current (previous) password.
Create a new password and enter it in the appropriate field. The password can be up to 16 digits and contain all ASCII symbols (a-z, A-Z, 0-9 and a selection of punctuation marks).
Confirm the new password by re-entering.
Confirm the new password by re-entering.
Save changes.
Admin passwordÂ
In this section, you can change the administrator password that is used to enter the web interface and monitor settings. To do it:Â
Enter the current (previous) password.
Create a new password and enter it in the appropriate field. The password can be up to 16 digits and contain all ASCII symbols (a-z, A-Z, 0-9 and a selection of punctuation marks).
Confirm the new password by re-entering.
Save changes.