Device settings
To access system settings, open the Pincode menu from the main screen, enter the settings password (by default, it is *123*), and press the Lock button.
As a result, the settings menu will be opened. To go to the necessary menu, press its icon.
Device
In this section, you can configure:
panel operation mode;
Wall mode is used when the panel is installed on the perimeter of the object. If this variant is chosen, on the panel you must enter Building No., Unit No., Floor No., and Apartment No. to call the necessary monitor.
Unit mode is required if the panel is installed near the unit entrance. When using this mode, it is enough to enter Floor No. and Apartment No. to call the necessary monitor.
device language: English, Ukrainian, Spanish, Polish, Dutch, Turkish, French, Danish, Portuguese, German, Russian;
panel logical address: Building No., Unit No., and Device No.;
For correct functioning, the panel and the monitor must have the same building and unit number in apartment settings. Also for monitors, you must indicate corresponding information about the floor, apartment, and device number.
If you have more than 1 entrance panel with the same logical address, you need to specify their device numbers, starting from 1 for the main device, and from 2 to 9 for others.
settings password for accessing the panel interface — separate from the web interface admin password, and can be disabled if needed;
level of panel speaker volume;
panel camera stream resolution: 640×480, 1280×720, or 1920×1080 (optional).