Electrical connection of AA-07FBC
After verifying whether a device is complete, you can switch to the connection step.
For connection you will need:
an Ethernet UTP CAT5 or higher cable connected to a network switch/router;
The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.
power supply at + 12V, 2 Amps;
wires must be brought for connecting the lock and additional modules (optional).
You can connect any type of electromechanical lock for which the switched current does not exceed 5 Amps.
The following are typical connection schemes of all elements to the entrance panel:
Connection using an uninterruptible power supply unit and an electromechanical lock
Connection using an uninterruptible power supply unit and external power supply for an electromechanical lock
Connecting an MR-03KP reader via SH-12
The MR-03KP keypad reader can be connected to the panel through the SH-12 interface module.
In this configuration:
the MR-03KP reader is connected to the SH-12 Wiegand Input;
SH-12 communicates with the panel through the RS-485 interface;
identifier data received by the reader is transferred to the panel via SH-12.
For detailed wiring instructions, see the SH-12 documentation.
Connection diagram: see the MR-03KP Electrical connection section.