Electrical connection of AA-07FBC

Electrical connection of AA-07FBC

After verifying whether a device is complete, you can switch to the connection step.

For connection you will need:

  • an Ethernet UTP CAT5 or higher cable connected to a network switch/router;

The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.

  • power supply at + 12V, 2 Amps; 

  • wires must be brought for connecting the lock and additional modules (optional). 

You can connect any type of electromechanical lock for which the switched current does not exceed 5 Amps.

The following are typical connection schemes of all elements to the entrance panel:

 

Connection using an uninterruptible power supply unit and an electromechanical lock

Connection using an uninterruptible power supply unit and external power supply for an electromechanical lock 

Connecting an MR-03KP reader via SH-12

The MR-03KP keypad reader can be connected to the panel through the SH-12 interface module.

In this configuration:

  • the MR-03KP reader is connected to the SH-12 Wiegand Input;

  • SH-12 communicates with the panel through the RS-485 interface;

  • identifier data received by the reader is transferred to the panel via SH-12.

For detailed wiring instructions, see the SH-12 documentation.

Connection diagram: see the MR-03KP Electrical connection section.