Call forwarding configuration
With the forwarding feature, you can configure calls to an indoor video entry phone (monitor) and SIP numbers.
How to configure call forwarding from an entrance panel
To configure this feature, you must connect to the device web interface via the Internet browser on your PC. The monitor and PC from which you plan to access the device must be connected to the same network segment.
1. Enter the IP address of the monitor in the address line of the browser. You can check the IP address with software for device search and upgrade or at monitor settings (if data was previously indicated).
2. Enter the username and the password in the opened window. By default, the username is admin, and the password is 123456.
3. Open the Forward tab and click New Forward.
4. Enter the Apartment Number which consists of the floor and room number. For example, 223 indicates apartment 23 located on the 2nd floor. Entering this number on the panel the queue will work.
5. Enter Forward Number (direction for call forwarding).
You can use 2 formats for numbers:
Format for internal calls: sip:1@192.168.1.65, where 1 is any number, 192.168.1.65 is the IP address of the monitor;
Format for SIP calls: sip:5588@us.sip.bas-ip.com, where 5588 is the SIP number of the device being called, us.sip.bas-ip.com SIP server address.
6. You can add up to 8 numbers for forwarding. After entering all required data, click Confirm.
7. Save this forward queue by clicking Confirm.